Column Buckling

Created on: 2025-01-31
Tags: #ColumnBuckling
Course: MOS


Definition

  • Structure Stability: Load doesn’t cause a sudden change in the configuration.
  • Higher loads in the columns can lead to compression and bending which is known as buckling.
  • The load for which buckling starts is known as critical load or $P_{cr}$.
  • The critical load is derived from Euler’s Formula for a pin-join column.

Pin-Connected Column

  • Centric axial load $P$.
  • If the reaction and axial force is aligned perfectly, then there would be no moment and hence no bending.
  • But this is not practical and hence we use beam deflection equations \(\frac{d^2y}{dx^2} = \frac{M}{EI}\)
  • In this case, $M= -Py$, where $P$ is a constant. \(\frac{d^2y}{dx^2} + \frac{Py}{EI} = 0\)
  • From the solution of the above differential equation, we have \(P = \frac{n^2\pi^2EI}{L_{e}^2}\)
  • The critical load is found for $n=1$.
  • The buckling occurs for the axis about the MOI (I) is lowest.

Free-Fixed Column

  • Half a pin connected column.
  • The effective length $(L_e)$ is twice the length of the column.

    Fixed-Fixed Column

  • Double a pin connected column.
  • The moment at the points $\frac{L}{4}$ and $\frac{3L}{4}$ is zero, similar to the pin connected column.
  • The effective length $(L_e)$ is half the length of the column.

Fixed-Pin Column

  • The effective length $(L_e)$ is 0.7 L.
  • The force balance leads to non-homogenous equation unlike the pin-pin condition and solution gives \(P_{cr} = \frac{20.19E^2I^2}{L^2} = \frac{\pi E^2I^2}{(0.7L)^2}\)